CBJQP - 1,2-DICHLOROETHANE, D-103

  • MSDS: CBJQP
  • Manufacturer: C D N ISOTOPES INC
  • Product Name: 1,2-DICHLOROETHANE, D-103
  • National Stock Number: 6810-00N068882
Product Identification

Product ID:1,2-DICHLOROETHANE, D-103
MSDS Date:08/10/1994
FSC:6810
NIIN:00N068882
MSDS Number: CBJQP

Responsible Party
C/D/N ISOTOPES INC
88 LEACOCK ST
POINT-CLAIRE, QUEBEC

Emergency Phone: 800-565-4696; 514-697-6254

Info Phone: 800-565-4696; 514-697-6254

Cage: CDNST

Contractor
C/D/N ISOTOPES INC
POINT-CLAIRE, QUEBEC

Telephone: 800-565-4696; 514-697-6254

Cage: CDNST

Ingredients

ETHANE, 1,2-DICHLORO-; (ETHYLENE DICHLORIDE) (C*2H*4CL*2)

CAS: 107-06-2

RTECS: KI0525000

OSHA PEL 50 PPM

ACGIH TLV: 10 PPM

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


1,2-DICHLOROETHANE-D4; (C*2D*4CL*2)

CAS: 17060-07-0

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50(ORAL,RAT):670 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:IRRITATION, NARCOSIS, NAUSEA, CORNEAL
CLOUDING, LIVER AND KIDNEY DAMAGE, CNS DEPRESSION. CANCER AND
MUTAGEN INDICATION.
Explanation of Carcinogenicity:ETHYLENE DICHLORIDE:IARC MONOGRAPHS,
SUPP, VOL 7, PG 56, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS,
1994:(SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN:WASH WITH WATER.
INGESTION:MEDICAL ASSISTANCE FOR GASTRIC LAVAGE. INHALATION:REMOVE
TO FRESH AI R. ARTIFICIAL RESPIRATION OR OXYGEN, IFNECESSARY.

Fire Fighting

Flash Point Method:CC
Flash Point:55.4F,13.0C
Lower Limits:6%
Upper Limits:15.9%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:FLAMMABLE, TOXIC PHOSGENE AND HCL FUMES
ON DECOMPOSITION. CANCER SUSPECT.

Accidental Release

Spill Release Procedures:PROVIDE ADEQUATE IGNITION-PROOF VENTILATION.
REMOVE ALL HEAT AND IGNITION SOURCES. ABSORB ON VERMICULITE AND
TRANSFER TO A CLOSED CONTAINER. WEAR A NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING APPARAT US, RUBBER BOOTS AND HEAVY RUBBER
GLOVES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CANCER SUSPECT. ADEQUATE VENTILATION.
PROTECT FROM LIGHT AND MOISTURE. GROUND METAL CONTAINERS WHEN
TRANSFERRING LIQUID.
Other Precautions:WEAR A NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS, RUBBER BOOTS AND HEAVY RUBBER GLOVES.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS.
Ventilation:FUMEHOOD TO MEET TLV REQUIREMENTS.
Protective Gloves:CHEMICAL & SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . PROTECTIVE CLOTHING AND RUBBER BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:ANTICIPATED TO BE CARCINOGEN. ANIMAL:GASTROINTESTINAL,
SKIN, LUNGS.

Chemical Properties

Boiling Pt:B.P. Text:181F,83C
Melt/Freeze Pt:M.P/F.P Text:95.0F,35.0C
Vapor Pres:87
Vapor Density:3.35
Spec Gravity:1.2 (H*2O=1)
Appearance and Odor:COLORLESS LIQUID WITH A PLEASANT CHLOROFORM LIKE
ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI METALS, REDUCING AGENTS, BASES (HYDROXIDES, AMINES).
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO/CO*2, PHOSGENE AND HCL FUMES ON
COMBUSTION.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . VIA LICENSED DISPOSAL COMPANY. DISPOSE OF ACCORDING
TO FEDERAL AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.